LED strip project kit builder
One row per zone: strip, voltage, run length, how many runs and the channel. The builder rounds each run to the strip's cut marks, cuts the channel, sizes the drivers per zone and adds it all into one list to send with the quote request.
Every zone, one bill of materials
The same rules as the cut length, channel and power supply calculators, applied to every zone at once.
Bill of materials
—
Order list
| Item | Qty |
|---|
By zone
| Zone | Strip · cut · feeds | Load | Drivers |
|---|
Each run is cut at the strip's cut marks, down to fit inside the measured length or up to cover it, as set above; reels are counted per model across zones. Drivers are sized per zone, smallest single unit at the loading rule, or several of the largest when one is not enough.
Send this list with the drawings and an engineer checks it against the layout before the quote.
Request a quoteFour rules behind the list
-
1
Strip to the cut marks
Each run is rounded up to the strip's cut unit at the chosen voltage. Reels are counted per model over all zones.
-
2
Feeds per run
A run longer than the model's length per feed needs another feed point, counted per run.
-
3
Channel like the cut list
Stick channels are cut from 2 m or 3 m lengths with offcuts reused; larger profiles ship cut to length up to 4 m. Covers, end caps and joiners follow.
-
4
Drivers per zone
Each zone's load is divided by the loading rule. With Class 2 on, the zone is split into 60 W outputs; otherwise the smallest driver that carries it is picked.
Reading the list
Why is the strip total longer than the runs?
Each run is rounded up to the strip's cut marks, because a strip can only be cut there. The builder counts what has to be cut, not the nominal length.
Why one driver set per zone instead of one for the job?
Zones are usually switched and dimmed on their own, and drivers sit near their loads to keep feed wires short. Sizing per zone matches how the job is wired.
What about the feed wire between driver and strip?
Size it with the voltage drop calculator once the driver locations are on the drawing; the length of the home run decides the gauge.
Is the list final?
It is a starting bill of materials. An engineer checks it against the drawings, the dimming system and the driver locations before the quote.
Send the list and the drawings
Paste the order list into the request. An engineer replies with the checked bill of materials and the quote, in writing.
- Trade & project orders
- Drawings welcome
- US-based support